Overview of Motion Programs
1.2.3 Feed Speeds
1 -36
There are three override setting methods: Motion program, ladder logic program, or the Parame-
ter Setting Screen.
Command speed × override = output speed
With MP900-series
Machine Controller
Override function
selection
Fixed parameter
No.17 bit 9
Enabled
Disabled
Override
(OWxx2C/
OWxx18)
Output
speed
(OLxx22/OLxx10)
Command
speed
(OLxx22/
OLxx10)
100%
(OWxx2C/OWxx18)
Note With the 2000-series Machine Controller, the Override value is always effec-
tive.
1. The Override value is always effective during operation. It can be changed in the ladder logic program,
motion program, and parameter settings while an axis is travelling.
2. If the output speed is out of range after adjustment for the override setting, a parameter setting error will
result.
J
Interpolation Feed Speed
D
The feed speeds for interpolation commands are designated by numbers following the letter
F. They are sometimes referred to as F designations.
D
The F designation for linear and circular interpolation designates the tangential speed.
INC MVS [X]1200 [Y]900 F500;
500
reference
unit/min
+Y
+X
F = 500 = 400
2
+ 300
2
[reference unit∕min]
300 reference unit/min
400 reference unit/min
Figure 1.5
Tangential Speed for 2-axis Linear Interpolation
z
Override
Override often means “to invalidate.” In this manual, however, it should be taken to mean “change” the set value.
TERMS
1
INFO
A
EXAMPLE
"