beautypg.com

7 main frequency reference – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 78

background image

V

I

Figure 3.22 DIP Switch S1

Table 3.13 DIP Switch S1 Settings

Setting Value

Description

V (left position)

Voltage input (0 to 10 V)

I (right position)

Current input (4 to 20 mA or 0 to 20 mA): default setting

Table 3.14 Parameter H3-09 Details

No.

Parameter Name

Description

Setting

Range

Default

Setting

H3-09 Frequency ref. (current)

terminal A2 signal level selection

Selects the signal level for terminal A2.

0: 0 to +10 V, unipolar input (with lower limit)

1: 0 to +10 V, bipolar input (no lower limit)

2: 4 to 20 mA

3: 0 to 20 mA

0 to 3

2

3.7 Main Frequency Reference

78

YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide