Single-phase 200 v, 1 model number and nameplate check – Yaskawa J1000 Compact Vector Control Drive User Manual
Page 29

CIMR - V U 2 A 0001 F A A
Drive
V1000
Series
No.
Customized
Specifications
A Standard model
Design
Revision
Order
No.
Region
Code
No.
Voltage Class
B
1-phase, 200-240 Vac
3-phase, 380-480 Vac
3-phase, 200-240 Vac
2
4
U
USA
<1> Refer to manual TOBPC71060635 for more information on these models.
<2> Refer to manual TOBPC71060621 for more information on these models.
<3> Drives with these specifications do not guarantee complete protection for the specified environmental condition.
No.
Environmental
Specification <3>
A
M
S
Standard
Humidity- and
dust-resistant
Vibration-resistant
No. Enclosure Type
IP00/Open-Chassis
B
A
IP20/Open-Chassis
F
IP20/NEMA Type 1
J
IP20/Finless <2>
L
IP00/Finless <2>
NEMA 4X/IP66 <1>
G
Refer to the tables below.
n
Single-Phase 200 V
Normal Duty
Heavy Duty
No.
Max. Motor
Capacity kW
Rated Output
Current A
No.
Max. Motor
Capacity kW
Rated Output
Current A
0001
0.2
1.2
0001
0.1
0.8
0002
0.4
1.9
0002
0.2
1.6
0003
0.75
3.3
0003
0.4
3.0
0006
1.1
6.0
0006
0.75
5.0
0010
2.2
9.6
0010
1.5
8.0
0012
3.0
12.0
0012
2.2
11.0
–
–
–
0018
3.7
17.5
Note:
Model BA0018 is available with a Heavy Duty rating only.
1.1 Model Number and Nameplate Check
YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide
29
1
Receiving