B.1 parameter table – Yaskawa J1000 Compact Vector Control Drive User Manual
Page 201

No.
Name
Description
L6-01
Torque Detection Selection 1
0: Disabled
1: oL3 at Speed Agree - Alarm
2: oL3 at RUN - Alarm
3: oL3 at Speed Agree - Fault
5: UL3 at Speed Agree - Alarm
6: UL3 at RUN - Alarm
7: UL3 at Speed Agree - Fault
8: UL3 at RUN - Fault
L6-02
Torque Detection Level 1
Sets the overtorque/undertorque detection level.
L6-03
Torque Detection Time 1
Sets the length of time an overtorque/undertorque condition must exist
before Torque Detection 1 is triggered.
L6-04
Torque Detection Selection 2
Refer to V1000 Technical Manual for details.
L6-05
Torque Detection Level 2
Refer to V1000 Technical Manual for details.
L6-06
Torque Detection Time 2
Refer to V1000 Technical Manual for details.
L6-08
Mechanical Weakening (OL5)
Detection Operation
Refer to V1000 Technical Manual for details.
L6-09
Mechanical Weakening Detection
Speed Level
Refer to V1000 Technical Manual for details.
L6-10
Mechanical Weakening Detection
Time
Refer to V1000 Technical Manual for details.
L6-11
Mechanical Weakening Detection
Start Time
Refer to V1000 Technical Manual for details.
L7: Torque Limit
Use L7 parameters to configure the torque limit function.
L7-01
Forward Torque Limit
Refer to V1000 Technical Manual for details.
L7-02
Reverse Torque Limit
L7-03
Forward Regenerative Torque
Limit
L7-04
Reverse Regenerative Torque
Limit
L7-06
Torque Limit Integral Time
Constant
Refer to V1000 Technical Manual for details.
L7-07
Torque Limit Control Method
Selection during Accel/Decel
Refer to V1000 Technical Manual for details.
L8: Hardware Protection
Use L8 parameters to configure hardware protection functions.
L8-01
Internal Dynamic Braking Resistor
Protection Selection (ERF type)
0: Resistor overheat protection disabled
1: Resistor overheat protection enabled
L8-02
Overheat Alarm Level
Refer to V1000 Technical Manual for details.
L8-03
Overheat Pre-Alarm Operation
Selection
Refer to V1000 Technical Manual for details.
L8-05
Input Phase Loss Protection
Selection
0: Disabled
1: Enabled
B.1 Parameter Table