B.1 parameter table – Yaskawa J1000 Compact Vector Control Drive User Manual

Page 184

background image

No.

Name

Description

d4-08

Frequency Reference Bias Upper

Limit (Up/Down 2)

When d4-06 is greater than d4-08, d4-08 becomes bias for upper limit.

d4-09

Frequency Reference Bias Lower

Limit (Up/Down 2)

When d4-06 is less than d4-09, d4-09 becomes bias for lower limit.

d4-10

Up/Down Frequency Reference

Limit Selection

0: Lower Limit is determined by d2-02 or analog input.

1: Lower Limit is determined by d2-02.

d7: Offset Frequency

Use d7 parameters to set the offset frequency.

d7-01

Offset Frequency 1

Refer to V1000 Technical Manual for details.

d7-02

Offset Frequency 2

Refer to V1000 Technical Manual for details.

d7-03

Offset Frequency 3

Refer to V1000 Technical Manual for details.

E1: V/f Pattern Characteristics

Use E1 parameters to set V/f characteristics for the motor.

E1-01

Input Voltage Setting

Refer to V1000 Technical Manual for details.

E1-03

V/f Pattern Selection

Refer to V1000 Technical Manual for details.

E1-04

Maximum Output Frequency

Only applicable when E1-03 is set to F.

E1-05

Maximum Output Voltage

Refer to V1000 Technical Manual for details.

E1-06

Base Frequency

Only applicable when E1-03 is set to F.

E1-07

Middle Output Freq.

Only applicable when E1-03 is set to F. To set linear V/f

characteristics, set the same values for E1-07 and E1-09.

E1-08

Middle Output Frequency Voltage

Only applicable when E1-03 is set to F.

E1-09

Minimum Output Frequency

Only applicable when E1-03 is set to F. To set linear V/f

characteristics, set the same values for E1-07 and E1-09.

E1-10

Minimum Output Frequency

Voltage

Only applicable when E1-03 is set to F.

E1-11

Middle Output Frequency 2

Only applicable when E1-03 is set to F.

E1-12

Middle Output Frequency Voltage

2

Only applicable when E1-03 is set to F.

E1-13

Base Voltage

Only applicable when E1-03 is set to F.

E2: Motor Parameters

Use E2 parameters to set motor-related data.

E2-01

Motor Rated Current

Sets motor nameplate full load current in amperes (A).

E2-02

Motor Rated Slip

Sets the motor rated slip in hertz (Hz).

E2-03

Motor No-Load Current

Sets the magnetizing current of the motor as a percentage of the motor

rated current (E2-01).

E2-04

Number of Motor Poles

Refer to V1000 Technical Manual for details.

E2-05

Motor Line-to-Line Resistance

Sets the phase-to-phase motor resistance in ohms.

E2-06

Motor Leakage Inductance

Sets the voltage drop due to motor leakage inductance as a percentage

of motor rated voltage.

B.1 Parameter Table

184