A.2 single/three-phase 200 v class drives – Yaskawa J1000 Compact Vector Control Drive User Manual
Page 166

Item
Specification
Three-Phase Drive Model
2A0001
2A0002
2A0004
2A0006
2A0010
2A0012
2A0020
Single-Phase Drive Model
<1>
BA0001
BA0002 BA0003 BA0006 BA0010 BA0012 BA0018
Harmonic Corrective
Actions
DC Link Choke
Optional
<1>
Drives with single-phase power supply input will output three-phase power and cannot run a single-phase motor.
<2>
2A0020 only. BA0018 is available with a Heavy Duty rating only.
<3>
The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps
should be equal to or greater than the motor rated current.
<4>
Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and
power supply impedance.
<5>
Rated motor capacity is calculated with a rated output voltage of 230 V.
<6>
Carrier frequency is set to 2 kHz (Swing PWM). Current derating is required in order to raise the carrier
frequency.
<7>
Carrier frequency is set to 10 kHz. Current derating is required in order to raise the carrier frequency.
<8>
Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
<9>
DC is not available for UL standards.
A.2 Single/Three-Phase 200 V Class Drives
166
YASKAWA ELECTRIC TOEP C710606 47C YASKAWA AC Drive – V1000 Quick Start Guide