H1 Multi-Function Digital Input Selections
H1-
Setting
Function
Description
41
Reverse Run Command (2-wire
sequence)
Open: Stop
Closed: Reverse run
42
Run Command (2-wire
sequence 2)
Open: Stop
Closed: Run
43
FWD/REV Command (2-wire
sequence 2)
Open: Forward
Closed: Reverse
44
Offset Frequency 1 Addition
Closed: Adds d7-01 to the frequency reference.
45
Offset Frequency 2 Addition
Closed: Adds d7-02 to the frequency reference.
46
Offset Frequency 3 Addition
Closed: Adds d7-03 to the frequency reference.
47
Node Setup
Closed: Node Setup for SI-S3/V enabled.
Note: Available in drive software versions PRG: 1016 and later.
60
DC Injection Braking
Command
Closed: Triggers DC Injection Braking (b2-02)
61
External Search Command 1
Closed: Activates Current Detection Speed Search from the max. output
frequency (E1-04) if b3-01 = 0.
62
External Search Command 2
Closed: Activates Current Detection Speed Search from the frequency
reference if b3-01 = 0. Activates Speed Estimation Type Speed search if
b3-01 = 0.
65
KEB Ride-Thru 1 (N.C.)
Open: KEB Ride-Thru 1 enabled
Closed: Normal operation
66
KEB Ride-Thru 1 (N.O.)
Open: Normal operation
Closed: KEB Ride-Thru 1 enabled
67
Communications Test Mode
Tests the MEMOBUS/Modbus RS-485/422 interface.
68
High-Slip Braking
Closed: High-Slip braking is executed. Drive stops.
6A
Drive Enable
Open: Drive disabled. If this input is opened during run, then the drive will
stop as specified by parameter b1-03.
Closed: Ready for operation.
75
Up 2 Command
Open: Maintains the current frequency reference
Closed: Increases or decreases the frequency reference.
76
Down 2 Command
7A
KEB Ride-Thru 2 (N.C.)
Open: KEB Ride-Thru 2 enabled
Closed: Normal operation
7B
KEB Ride-Thru 2 (N.O.)
Open: Normal operation
Closed: KEB Ride-Thru 2 enabled
7C
Short-Circuit Braking (N.O.)
Open: Normal operation
Closed: Short-Circuit Braking
7D
Short-Circuit Braking (N.C.)
7E
Forward/Reverse Detection
Direction of rotation detection (for Simple V/f w/PG)
90 to 96 DriveWorksEZ Digital Input 1
to 7
These settings are for digital input functions used in DriveWorksEZ.
Normally there is no need to change or apply these settings.