Local output functionality – Yaskawa MotionWorks+ Windows Software User Manual
Page 205
MotionWorks+™
Standardized Template Project
199
Local Output Functionality
Output
Functionality
Description
MW+ Name
All Modes
°
All Modes
°
Local_Output1
Servo Enabled
On when Servo Enabled
Local_Output2
Manual Mode
On when in Manual Mode
Local_Output3 Automatic Mode On when in Automatic Mode
Local_Output4 Homed / Homing On when homed, flashing while homing, Off otherwise
°
Manual Mode
°
Local_Output5
Jogging Fwd
Flashing when jogging forward, until max jog speed achieved, then on solid
Local_Output6
Jogging Rev
Flashing when jogging reverse, until max jog speed achieved, then on solid
Local_Output7
Homing
Flashing while homing, on solid when homed, off otherwise
Local_Output8 Applying Torque Flashing while applying torque, on solid when applied torque=requested torque
°
Automatic Mode °
Local_Output5
Index
On while indexing
Local_Output6
Gear
On while Gearing
Local_Output7
Cam
On while Camming, Flashing when engaging/disengaging camming
Local_Output8
Latch
On during latch routine
°
While Indexing °
Local_Output6
PLS
On first third of move
Local_Output7
PLS
On second third of move
Local_Output8
PLS
On last third of move
°
While Latching °
Local_Output5
PLS
On before Latch Window Starts
Local_Output6
PLS
On during Latch Window
Local_Output7
PLS
On after Latch Window Ends until default distance reached