4 change dynamics – Yaskawa MotionWorks+ Windows Software User Manual
Page 143
![background image](https://www.manualsdir.com/files/819544/content/doc143.png)
MotionWorks+™
Block Reference
137
3.2.4
CHANGE DYNAMICS
Definition
This block changes acceleration, deceleration, velocity, and s-curve settings while the
servo is already in motion. This block does not initiate motion. A previously set target
position will remain unchanged. Leaving a property blank (zero value) does not affect
current settings when this block executes.
Properties
Acceleration:
The acceleration rate of the servo in user units / second
2
.
Deceleration:
The deceleration rate of the servo in user units / second
2
.
S-Curve:
The amount of s-curve acceleration/deceleration in millisec-
onds.
Velocity:
The velocity of the move profile in user units / second.
Required Conditions
The servo must already be in motion via a block such as MOVE AXIS, JOG,
LATCH TARGET, GEAR for the property updates to have any effect.
Property
Default
Minimum
Value
Maximum
Value
Base Units
Run
Time
Acceleration
0
32767
0 ms to rated speed
Yes
Deceleration
0
32767
0 ms from rated speed
Yes
S-curve
0
0
32767 ms
Yes
Velocity
0
-200.00
200.00 % of rated speed
Yes
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)