113
84
132
Absolute Encoder Data
Error
Received absolute data is abnormal.
85
133
Absolute Encoder Over-
speed
The encoder was rotating at a high speed
when the power was turned on.
86
134
Encoder Overheated
The internal temperature of the encoder is
too high.
99
153
Not an Alarm
Everything in the servo amplifier is OK.
91
145
Overload Warning
This warning occurs before either of the
overload alarms (71h or 72h). If the warn-
ing is ignored and operation continues, a
regenerative overload alarm may result.
92
146
Regenerative Overload
Warning
This warning occurs before alarm (32h). If
the warning is ignored and operation con-
tinues, a regenerative overload alarm may
result.
94
148
MP940 Data Setup Warn-
ing
Invalid or out of range data. See the
MP940 alarms for more information.
95
149
MP940 Invalid Command
Warning
Inappropriate command was issued for the
current control state.
9F
159
Option Card Warning
(MP940)
This warning indicates something is wrong
on the MP940. Typically it is an I/O error,
such as external encoder disconnected.
B1
177
Reference Speed Input
Read Error
The A/D converter for reference speed
input is faulty.
B2
178
Reference Torque Input
Read Error
The A/D converter for reference torque
input is faulty.
BF
191
System Alarm
A system error occurred in the servo
amplifier.
C1
193
Servo Overrun Detected
The servo motor ran out of control.
C8
200
Absolute Encoder Clear
Error and Multi-Turn Limit
Setting Error
The multi-turn for the absolute encoder
was not properly cleared or set.
C9
201
Encoder Communica-
tions Error
Communications between servo amplifier
and encoder is not possible.
CA
202
Encoder Parameter Error Encoder parameters are faulty.
CB
203
Encoder Echoback Error
Contents of communications with the
encoder is incorrect.
CC
204
Multi-Turn Limit
Disagreement
Different multi-turn limits have been set in
the encoder and servo amplifier.
D0
208
Position Error Pulse
Overflow
Position error pulse exceeded parameter
Pn505. This is only for position mode, not
used when MP940 is connected.
SGDH Front
Panel (Hex)
mAlarm_Servo_
Code (Dec)
Alarm Name