HEIDENHAIN TNC 620 (81760x-02) User Manual
Page 602

Tables and overviews
18.1
Machine-specific user parameters
18
602
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 2/2015
Parameter settings
ProbeSettings
Configuration of tool measurement
TT140_1
M function for spindle orientation
-1: Spindle orientation directly via NC
0: Function inactive
1 to 999: Number of M function for spindle orientation
Probing routine
MultiDirections: Probe from several directions
SingleDirection: Probe from one direction
Probing direction for tool radius measurement
X_Positive, Y_Positive,X_Negative, Y_Negative, Z_Positive, Z_Negative (depending
on tool axis)
Distance of tool lower edge to probe contact upper edge
0.001 to 99.9999 [mm]: Offset of stylus to tool
Rapid traverse in probing cycle
10 to 300 000 [mm/min]: Rapid traverse in probing cycle
Probing feed rate with tool measurement
1 to 3 000 [mm/min]: Probing feed rate with tool measurement
Calculation of probing feed rate
ConstantTolerance: Calculation of probing feed rate with constant tolerance
VariableTolerance: Calculation of probing feed rate with variable tolerance
ConstantFeed: Constant probing feed rate
Type of speed determination
Automatic: Determine speed automatically
MinSpindleSpeed: Use minimum spindle speed
Max. permissible rotational speed on cutting edge
1 to 129 [m/min]: Permissible rotational speed on cutter circumference
Maximum permissible speed with tool measurement
0 bis 1 000 [1/min]: Maximum permissible speed
Maximum permissible measurement error with tool measurement
0.001 to 0.999 [mm]: First maximum permissible measurement error
Maximum permissible measurement error with tool measurement
0.001 bis 0.999 [mm]: Second maximum permissible measurement error
NC stop during tool check
True: When breakage tolerance is exceeded the NC program is stopped
False: The NC program is not stopped