Converting a string parameter to a numerical value, String parameters 9.11 – HEIDENHAIN TNC 620 (81760x-02) User Manual
Page 345

String parameters
9.11
9
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 2/2015
345
Converting a string parameter to a numerical value
The
TONUMB function converts a string parameter to a numerical
value. The value to be converted should be only numerical.
The QS parameter must contain only one numerical
value. Otherwise the TNC will output an error
message.
Select Q-parameter functions
Select the
FORMULA function
Enter the number of the parameter in which the
TNC is to save the numerical value. Confirm with
the
ENT key
Shift the soft-key row
Select the function for converting a string
parameter to a numerical value
Enter the number of the QS parameter to be
converted, and confirm with the
ENT key
Close the parenthetical expression with the
ENT
key and confirm your entry with the
END key
Example: Convert string parameter QS11 to a numerical
parameter Q82
37 Q82 = TONUMB ( SRC_QS11 )
- TNC 122 User Manual (63 pages)
- TNC 122 Technical Manual (70 pages)
- TNC 360 Service Manual (157 pages)
- TNC 416 Technical Manual (510 pages)
- TNC 335 Technical Manual (581 pages)
- TNC 360 User Manual (237 pages)
- TNC 360 ISO-Programmierung (2 pages)
- TNC 415 (280 540) User Manual (227 pages)
- TNC 370D (92 pages)
- TNC 416 (289 pages)
- TNC 415 (280 540) Technical Manual (752 pages)
- TNC 415 (259 96x) Service Manual (195 pages)
- TNC 407 (280 580) User Manual (376 pages)
- iTNC 530 (340 420) Pilot (104 pages)
- TNC 407 (280 580) ISO Programming (333 pages)
- TNC 415 (280 540) Service Manual (252 pages)
- PT 880 Installation (112 pages)
- ND 100 User Manual (116 pages)
- ND 287 User Manual (147 pages)
- ND 280 Quick Start (12 pages)
- ND 200 (156 pages)
- ND 282 (10 pages)
- ND 287 Quick Start (26 pages)
- ND 282 B (39 pages)
- ND 281 A (44 pages)
- ND 281 B v.1 (53 pages)
- ND 281 B v.2 (65 pages)
- ND 221 v.2 (10 pages)
- ND 231 B v.2 (56 pages)
- ND 231 B v.1 (44 pages)
- ND 221 B v.2 (45 pages)
- ND 550 v.2 (8 pages)
- NDP 560 (10 pages)
- ND 523 (93 pages)
- ND 570 (8 pages)
- ND 750 v.2 (46 pages)
- ND 760 v.3 (72 pages)
- ND 770 v.1 (40 pages)
- ND 770 v.3 (41 pages)
- ND 760 E (44 pages)
- IOB 49 (21 pages)
- NDP 960 (68 pages)
- ND 780 Installation (132 pages)
- ND 970 (47 pages)
- ND 1100 Quick Start (36 pages)