Miscellaneous functions for path behavior

10.4

10

TNC 620 | User's Manual

HEIDENHAIN Conversational Programming | 2/2015

379

Suppressing touch probe monitoring: M141

Standard behavior

When the stylus is deflected, the TNC outputs an error message as

soon as you attempt to move a machine axis.

Behavior with M141

The TNC moves the machine axes even if the touch probe is

deflected. This function is required if you wish to write your own

measuring cycle in connection with measuring cycle 3 in order to

retract the stylus by means of a positioning block after it has been

deflected.

Danger of collision!

If you use M141, make sure that you retract the

touch probe in the correct direction.
M141 functions only for movements with straight-

line blocks.

Effect

M141 is effective only in the block in which it is programmed.
M141 becomes effective at the start of block.