Test run and program run 16.4 test run – HEIDENHAIN TNC 620 (81760x-02) User Manual
Page 550

Test run and program run
16.4 Test run
16
550
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 2/2015
Execute test run
If the central tool file is active, a tool table must be
active (status S) to conduct a test run. Select a tool
table via the file manager in the
Test Run mode of
operation.
You can select any preset table (status S) for the test run.
After
RESET + START, line 0 of the temporarily loaded preset
table automatically displays the momentarily active datum from
Preset.pr (execution). Line 0 is selected when starting the test run
until you define another datum in the NC program. All datums from
lines > 0 are read by the control from the selected preset table of
the test run.
With the
BLANK IN WORK SPACE function, you activate working
space monitoring for the test run, .see "Showing the workpiece
blank in the working space (option 20)", page 546.
Select the
Test Run operating mode
Call the file manager with the
PGM MGT key and
select the file you wish to test
The TNC then displays the following soft keys:
Soft key
Functions
Reset the blank form and test the entire
program
Test the entire program
Test each program block individually
Halt test run (soft key only appears once you
have started the test run)
You can interrupt the test run and continue it again at any point
—even within a fixed cycle. In order to continue the test, the
following actions must not be performed:
Selecting another block with the arrow keys or the
GOTO key
Making changes to the program
Selecting a new program