Unbinding luns for reconfiguration – Grass Valley Profile XP Aug 16 2004 User Manual
Page 91

Unbinding LUNs for reconfiguration
23 July 2004
Profile XP System Guide
91
9. Upon 100% completion, click
Close
in Progress Report window.
10. When the reboot message appears, click
OK
, then reboot the Windows operating
system on the Profile XP media platform. Afterward, the system is ready for
operation.
Unbinding LUNs for reconfiguration
Unbinding may be necessary to reconfigure the disk modules in the RAID storage
system. You must unbind a LUN before you can bind the disk modules in a different
configuration.
When redeploying an Expansion Chassis that was bound using a PFR500 or PFR600
RAID Controller Chassis, always use the GVG Disk Utility to unbind the disk modules
in the expansion chassis before disconnecting them from the original RAID Controller
chassis.
CAUTION: Unbinding destroys all user media files stored on the disk modules.
This section includes the following procedures:
• Unbinding LUNs: PFC500 and PFR700 Storage Systems
• Unbinding LUNs: PFR500 and PFR 600 Storage Systems
Unbinding LUNs: PFC500 and PFR700 Storage Systems
If you need to unbind LUNs, perform the following:
1. Start Configuration Manager using the desktop shortcut or by selecting
Start |
Programs | Profile Applications | Configuration Manager
.
2. In Configuration Manager, click
File System
to start the GVG Disk Utility.
3. Expand the tree view and identify bound LUNs.
!