Resetting the pfc500 system clock, Resetting the pfc500 system clock, Resetting the pfc 500 system clock – Grass Valley Profile XP Aug 16 2004 User Manual
Page 117

Resetting the PFC 500 system clock
23 July 2004
Profile XP System Guide
117
2. Enter network settings for the RAID chassis.
3. For each SNMP manager to which you want to send SNMP trap messages, enter
the IP address of the PC hosting the manager. If you are monitoring the PFR700/E
with NetCentral, enter the IP address of the NetCentral server (NetCentral 4.x and
higher) or NetCentral monitoring station (NetCentral 3.x and lower).
4. Click
OK
to save settings and close.
5. Restart the RAID chassis to put SNMP configuration changes into effect.
Resetting the PFC 500 system clock
Use the following procedure to set the system clock on all PFC500 RAID Storage
chassis connected. This procedure sets the PFC500 RAID controller clock to the
Profile XP system clock (or the clock of the machine on which the Disk Utility is
running).
To reset the PFC500 clock:
1. In the GVG Disk Utility tree view, right-click the PFC500 node, then select
Reset Clock
in the context menu.
2. On receiving an operation successful message, click
OK
.