Reference genlock ltc timecode gpi i/o, Electrical specifications – Grass Valley Profile XP Aug 16 2004 User Manual
Page 315

Electrical Specifications
23 July 2004
Profile XP System Guide
315
Reference Genlock
LTC Timecode
GPI I/O
Characteristics
Description
Color Field Detection, Based on
SCH Phase
Requirement:
Correct color framing for signals having an
average SCH phase
±40°; Lockup ±10°
Supplemental Data:
Once locked to color field, it will stay locked
over a range of 0
° to ±90°
Burst Frequency Lock Range
Requirement:
PAL,
±10 Hz at subcarrier
NTSC,
±20 Hz at subcarrier
Signal Amplitude Lock Range
Requirement:
Stays locked to +6 dB and -3 dB
Reference Genlock Input Return
Loss
Requirement:
≥40 dB to 5 MHz
Unlocked 27Mhz. clock accuracy
Requirement:
When not locked to a reference black
27Mhz. will be within
± 25PPM
Tri-level sync Lock Range
(high-definition)
Requirement:
Stays locked to +6 dB and -3 dB at nominal
±300 mV signal
Characteristics
Description
Input
Supplemental Data:
Longitudinal Time Code. AC coupled,
differential input
Input Impedance
Supplemental Data:
20 k
Ω.
Input Amplitude
Supplemental Data:
0.1 V p-p, differential, minimum
Maximum Input Voltage
Supplemental Data:
2.5 V p-p, differential, maximum
Characteristics
Description
GPI Input
Supplemental Data:
Inputs set to TTL level high.
Compatible with 5 volts CMOS/TTL open
collector or contact closures.
GPI Output
Supplemental Data:
Outputs are open drain drivers.
Max. voltage when outputs are open = 30V
Max. current when outputs are
closed = 200ma.