beautypg.com

Reference genlock ltc timecode gpi i/o, Electrical specifications – Grass Valley Profile XP Aug 16 2004 User Manual

Page 315

background image

Electrical Specifications

23 July 2004

Profile XP System Guide

315

Reference Genlock

LTC Timecode

GPI I/O

Characteristics

Description

Color Field Detection, Based on
SCH Phase

Requirement:

Correct color framing for signals having an
average SCH phase

±40°; Lockup ±10°

Supplemental Data:

Once locked to color field, it will stay locked
over a range of 0

° to ±90°

Burst Frequency Lock Range

Requirement:

PAL,

±10 Hz at subcarrier

NTSC,

±20 Hz at subcarrier

Signal Amplitude Lock Range

Requirement:

Stays locked to +6 dB and -3 dB

Reference Genlock Input Return
Loss

Requirement:

≥40 dB to 5 MHz

Unlocked 27Mhz. clock accuracy

Requirement:

When not locked to a reference black
27Mhz. will be within

± 25PPM

Tri-level sync Lock Range
(high-definition)

Requirement:

Stays locked to +6 dB and -3 dB at nominal

±300 mV signal

Characteristics

Description

Input

Supplemental Data:

Longitudinal Time Code. AC coupled,
differential input

Input Impedance

Supplemental Data:

20 k

Ω.

Input Amplitude

Supplemental Data:

0.1 V p-p, differential, minimum

Maximum Input Voltage

Supplemental Data:

2.5 V p-p, differential, maximum

Characteristics

Description

GPI Input

Supplemental Data:

Inputs set to TTL level high.
Compatible with 5 volts CMOS/TTL open
collector or contact closures.

GPI Output

Supplemental Data:

Outputs are open drain drivers.
Max. voltage when outputs are open = 30V
Max. current when outputs are
closed = 200ma.

This manual is related to the following products: