beautypg.com

Switching fabric modules – H3C Technologies H3C S10500 Series Switches User Manual

Page 87

background image

77

Switching fabric modules

Follow these restrictions and guidelines when you install switching fabric modules:

Do not install A-type switching fabric modules (LSU1FAB04A0 and LSU1FAB08A0) and LPUs with
LSUM-prefixed model numbers on the same switch.

Do not install switching fabric modules of different types on the same switch.

For the S10504, S10508, S10508-V, or S10512 switch, make sure a minimum of one switching
fabric module is installed in either of the two lowest numbered switching fabric module slots.

{

Slot 6 or 7 on the S10504.

{

Slot 10 or 11 on the S10508 or S10508-V.

{

Slot 14 or 15 on the S10512.

H3C recommends that you use the two lowest numbered switching fabric module slots for
installation first.

The console port of the switching fabric module for the S10500 is used for H3C Support to maintain
the switches. Do not use the console port if you have not been trained for that.

Table 28 Available switching fabric modules and specifications

Chassis

model

Switching fabric

module model

SDRAM Connector Port Installation

requirements

S10504

LSU1FAB04A0
(LSUM1FAB04A0)

1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.

LSU1FAB04B0
(LSUM1FAB04B0) 1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.

LSU1FAB04D0
(LSUM1FAB04D0)

1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.

S10506 LSUM1FAB06C0

1

GB

RJ-45

One console
port

A maximum of two
switching fabric modules

are required.

S10508

S10508-V

LSU1FAB08A0
(LSUM1FAB08A0) 1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.

LSU1FAB08B0
(LSUM1FAB08B0) 1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.

LSU1FAB08D0
(LSUM1FAB08D0) 1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.

S10510 LSUM1FAB10C0

1

GB

RJ-45

One console
port

A maximum of two
switching fabric modules

are required.

S10512

LSU1FAB12B0
(LSUM1FAB12B0) 1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.

LSU1FAB12D0
(LSUM1FAB12D0) 1 GB

RJ-45

One console
port

Two to four switching fabric
modules are required.