response. It depends on the network speed. (only available when working

with Welltech external RTP resource server).

System Announcement: Used when personal announcement cannot be

located (e.g. user not found).

Invalid TTL Process: Response policy when register expired is too small.

-

Use Proxy TTL

: Response proxy expires time to UAC and expect it will use

it as default TTL.

-

Reject

: Send 423 Interval Too Brief to UAC.

AAA Sending Stage: Send AAA message before or after DM (Digit

Manipulation).

Global Call Validation: Call Validation through both parties, none, Caller or

Called.

Use Local Time: Enable to use local time or not.

Missed Call From Domain: Domain of missed call, use none, IP address or

domain name.

Missed Call Tel No: Telephone number of missed call, use TEL No or

replace_ANI .

Camp on Timeout: When user camp on a call, the maximum time to wait

before called extension to become free.

Web Call: Enable to use demo web call for subscriber or not. It requires the

web call license from Welltech.

Web Call ID: The demo web caller ID, you can get a number by click .

Camp On Codec: The codec will be used for a camp on calls. It is required to

use a most of common codec within your IP-PABX.

Change Call-ID: Whether change the call-ID in the SIP message when forking

a call out. Please contact Welltech Engineer when you want to change it.

Dedicate UAC Failure: It is used when you are using dedicated UAC feature.

If a subscriber is using the dedicate UAC ID and it is not registered, this

option will decide which actions will be taken. Select “Local Prefix Routing”

when you would like to use backup route. Select “Disconnect” when you are

not allowed using backup route.

BLF (RFC 4235) State Code: Busy Lamp Field State Code when report the

subscriber status to other Subscriber.

- Unavailable: The default is “void”.

- Idle: The default is “terminated”.

- Ringing: The default is “early”.

Subscriber server-based 302: Enable Server based 302 Move or not. When it

is enabling, the 302 will be processed by SIPPBX 6200x instead of sending it

to caller.

** SIP and network knowledge is required to change these parameters.

Debug

Debug can be turned ON or OFF based on each system module and level

to minimum the debug information.

Please only turn on the debug information

for debug purpose under Welltech FAE's instruction and turn off when

debug job was complete. Or, the SIPPBX 6200x system performance will be

greatly affected badly.

Start Path: System Core > Debug