Scada details screen, Scada details screen -26 – Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual
Page 56

3-26
W A N s u i t e 5 3 7 0
SCADA Details Screen
NOTICE:
SCADA traffic has a higher priority than other types of traffic flowing
through the unit. Refer to Normal Tx Queue Size on page 3-21 for more
details.
Click on “SCADA” under the “Type” column on the Services screen to view
the SCADA Details screen (Figure 3.20). This menu gives you access to the
configuration parameters described in the paragraphs below.
Figure 3.20
SCADA Details Screen
Message Size
Maximum number of characters to buffer before sending a frame.
Values: 0
−
1024
Default: 256
Idle Character Delay
Maximum number of idle character time to wait before sending a frame.
Values: 0
−
65535
Default: 10
Input Terminator
Decimal value of the character that terminates a message before sending a
frame.
Values: 0
−
255
Default: 0
Data Direction
Data direction that the port will support. If set to “Input,” the port will only
accept incoming data and will not transmit data. If set to “Output,” the port
will ignore any incoming data. If set to “Both,” the port will process all data.
Values: Input, Output, Both
Default: Both