V T 1 0 0 I n t e r f a c e
4-77
Filter Ageing Timer
Specifies the length of time an entry in the lookup table will be held if no
traffic is received from the specified MAC Address.
Values: 1
−
65535 s
Default: 300 s
The Bridge Details screen provides the following user-activated prompts:
Figure 4.77
Bridge Port Table
The Bridge Port Table screen lets you view the parameters described below
the Bridge Port Details screen. Clicking on a number in the
the Bridge Port Table will bring up the Bridge Port Details screen, which
displays, and, in some cases, lets you change, the parameters described below.
Prompt
Function
Bridge Port Table
Displays the Bridge Port Table screen (Figure 4.77) that lets
the user access and configure the Bridge Port Details screen
(Figure 4.78).
Bridge Lookup Table
Displays the Bridge Lookup Table screen (Figure 4.79) that
contains all MAC Addresses learned by the Bridge.