beautypg.com

Network config screen, Error status and alarm thresholds table, Network config screen -7 – Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual

Page 123: Error status and alarm thresholds table -7

background image

V T 1 0 0 I n t e r f a c e

4-7

From the Interfaces screen, you may choose from the following: Network,
Serial 1, Serial 2, Auxiliary, 10/100 Ethernet, or Supervisory. Each of these
interfaces is described below.

Network Config Screen

The Network Config screen (Figure 4.7) lets you view and make changes to
the Network interface's configuration as described below. In addition, this
screen provides a table that displays the alarm values for the Network
interface.

Figure 4.7

Network Config Screen

Mode

Selects the network service type.

Values

DDS I 56K, DDS II CC-64K

Default: DDS I 56K

Timing

Sets the timing source to synchronize the unit’s internal timing generators.
Choices are as follows:

Internal – The unit’s internal frequency standard is used for all timing.

Network – Timing is derived from the network recovered clock. (Most
applications use this selection.)

Values: Network, Internal
Default: Network

NOTICE:

Internal timing is valid only in 56K mode.

Error Status and Alarm Thresholds Table

The unit can be programmed to generate an alarm condition based on a
specific level of performance degradation. The Network screen presents a
table that provides current error status, alarm condition, error count, and alarm
threshold information.

Acceptable alarm thresholds are set for periods of 1-5, 10, 20, or 30 seconds
(900 seconds), and are sampled every second. The types of error conditions

This manual is related to the following products: