W A N s u i t e 5 3 7 0

The four columns of the status table are as follows:

The table provides error status and alarm threshold information for the
following error parameters:

LOS

Sets the Loss of Signal threshold. A LOS is a 1-second period in which the
DDS received signal is interrupted. The default value is None.

OOF

Sets the Out of Frame threshold. An OOF is a 1-second period in which a
frame sync loss occurred. The default value is None.

OOS

Sets the Out of Service threshold. An OOS is a 1-second period during which
the Out of Service code is received. The default is None.

BPV

Sets the Bipolar Violation Errored threshold. A BPV is a 1-second period in
which at least one bipolar violation occurred. The default is None.

Reset Timer

The status table also provides a means for establishing the Reset Timer
threshold. This read/write field is used to establish the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset. The default value is 30.

The Network screen provides the following user-activated buttons:

Serial 1 and Serial 2 Screens

Because the Serial 1 and Serial 2 screens have the same menus, only the
Serial 1 screen is displayed below in Figure 3.5. The Serial screens let you
view and make configuration changes to the unit’s Serial 1 or Serial 2
interface as described below. To make changes to any Serial port parameter,
simply set the parameter to the desired selection and press the “Submit”
button.

Status

Displays the current status of the network port.

Alarm

Displays the alarm value of the network port. The unit
declares an alarm as soon as the count exceeds the established
threshold.

Count

Displays the number of events or occurrences of this
condition that have been detected.

Threshold

This forced-choice field can be set to a desired threshold for a
specific error condition. Available threshold choices are
None, 1, 2, 3, 4, 5, 10, 20, and 30.

Button

Function

Submit

Sets any values that have been changed.

Clear Alarms

Resets the alarm conditions and counts to zero.