beautypg.com

Verilink WANsuite 5370 (34-00310.D) Product Manual User Manual

Page 51

background image

W e b S e r v e r I n t e r f a c e

3-21

N1

Indicates the number of “keep alive” status inquiries that are sent between full
status requests.

Values: 5–255
Default: 5 if interface is Network (UNI), 6 if interface is Serial (NI).

N2

Specifies the total number of link reliability errors and protocol errors that can
occur during the sliding event monitor count defined by N3. If this count is
exceeded, the port is declared inactive.

Values: 1–255
Default: 3

N3

Represents a Monitored Events Count. For a network, a monitored event is
the receipt of a status inquiry message or the expiration of the polling
verification timer T2. For a FRAD, a monitored event is the transmission of a
status inquiry message. This parameter defines the size of the sliding window
used by the unit to determine whether a channel or user device is active.

Values: 5–255
Default: 4

T1

Specifies the number of seconds the unit waits between issuing status inquiry
messages.

Values: 5–30
Default: 10

RFC1315 Trap

When this parameter is set to “Enable,” the unit will send the standard
RFC1315 frame relay DTE circuit state change trap every time a DLCI
changes state, provided at least one destination IP address for trap is
configured in the SNMP configuration.

Values: Disable, Enable
Default: Disable

Normal Tx Queue Size

Each Frame Relay service has two distinct transmit queues: one for normal-
priority traffic and one for high-priority traffic. At this time, only SCADA and
TCP Server traffic are considered high-priority and are placed in the high-
priority queue. All other types of traffic are placed in the normal-priority
queue.

This parameter defines how many normal priority frames can be put in front
of a high-priority frame. The software always checks for high-priority frames
before placing normal-priority frames in the transmit queue. However, once
the frames are in the hardware transmit queue, their order of transmission
cannot be changed.

If SCADA and/or TCP Server are not up, set this parameter to 28 (the
default). If SCADA and/or TCP Server are up, set this parameter according to
the SCADA host system’s ability to support higher latency. For example, if a
SCADA host system has a timeout of 500 ms when polling remote devices
through a DDS Frame Relay service, the Normal Tx Queue Size parameter
should be set to 2. This would allow two 1500-byte IP frames to be sent
between SCADA frames without reaching the 500-ms limit. If the SCADA
host application has a timeout lower than 500 ms, this parameter should be set
to 1. This then ensures a minimum latency for SCADA applications.

This manual is related to the following products: