V T 1 0 0 I n t e r f a c e

4-37

Be (bps)

If an Excess Burst Rate is configured here, its value (in bits per second) will
be used instead of the default excess burst of the frame relay service.

Values: 0–64 k
Default: 0

Bc (bps)

If CIR enforcement is configured to “Yes,” the unit will throttle the
Committed Burst down to this value (in bits per second) when frames are
received with the BECN bit set.

Values: 0–64 k
Default: 0

Discard Eligible Flag

If this parameter is set to “Yes,” and CIR enforcement is also set to “Yes,”
the unit will set the Discard Eligible (DE) bit for frames sent over CIR.

Values: Yes, No
Default: No

In Band Management

If the unit is to be used as a gateway to reach a remote WANsuite 5370
through this DLCI, set this parameter to “Yes,” and configure the remote IP
address and Mask in the corresponding endpoint.

Values: Yes, No
Default: No

FrameStart Delay

If this parameter is set to “Enable,” the unit will send FrameStart discovery
and delay frames on this DLCI, and will report the state of the remote
Verilink FSx unit. It will also send SOS frames when the FRAD/router
connected to this unit goes inactive.

Values: Enable, Disable
Default: Enable if Auto Discovery is set to “Yes”; otherwise Disable

FrameStart Status

If the remote unit is a Verilink unit with FrameStart technology and
FrameStart Auto Discovery is enabled, the FrameStart Status field will show
the status of the remote unit. The status is “Active” if both the local and
remote DLCIs are active and the remote unit answers to the discovery frames
sent by this unit. The status is “SOS” if the remote unit is active but the
FRAD/router connected to it is inactive. The status is “Inactive” in all other
cases.

Values: Active, Inactive, SOS
Default: Inactive

Remote DLCI

If the remote unit is a Verilink unit with FrameStart technology, and
FrameStart Auto Discovery is enabled, this field displays the DLCI number
used on the remote end of this DLCI.

Values: 16

1023

Default: 0