Measurement Computing Personal488 rev.3.0 For DOS & Windows 3.Xi User Manual
Page 380
![background image](https://www.manualsdir.com/files/797818/content/doc380.png)
IV. TROUBLESHOOTING
19. Error Messages
Personal488 User’s Manual, Rev. 3.0
IV-365
74
UNKNOWN DOS DEVICE NAME
Driver488 DOS device name not known.
Must create Driver488 DOS device
name with the Make Dos Name
command.
75
UNABLE TO ALLOCATE MEMORY FOR NEW
DEVICE
Ran out of memory. Remove some devices
to restore memory.
76
UNKNOWN SLAVE DEVICE
Internal system error. Report to factory.
77
SLAVE DEVICE NOT SPECIFIED
Corrupt initialization file. Run the Install
program.
78
UNABLE TO CREATE DOS DEVICE NAME
Internal system error. Report to factory.
79
UNABLE TO INITIALIZE DEVICE
Corrupt initialization file. Run the Install
program.
80
ATTEMPTED TO REMOVE SLAVE DEVICE
Attempt to remove device which is required
for operation by another device.
81
DATA OVERRUN
Serial input overflow.
82
(None)
(None)
83
FRAMING ERROR
Serial data corrupt. Possible incorrect
Serial port configuration.
84
TIME OUT ON SERIAL COMMUNICATION
Serial device did not respond.
85
UNKNOWN PARAMETER OF TYPE %d
SPECIFIED :\n %s = %s
Internal system error. Report to factory.
86
BUS ERROR - NO LISTENERS
No Listeners found on bus.
87
TIME OUT ON MONITOR DATA
Expected terminator was not received.
88
INVALID VALUE SPECIFIED
Specified value is invalid for application.
See command for proper value types.
89
NO TERMINATOR SPECIFIED
Terminator must be specified. Check
terminator value.
90
NOT AVAILABLE IN 8-BIT SLOT
Specified option is not available when the
I/O adapter is fitted into an 8-bit slot.
91
TOO MANY PENDING EVENTS
Internal system error. Report to factory.
92
BREAK ERROR
Serial receiver detected break.
93
UNEXPECTED CHANGE OF CONTROL
LINES
Handshake lines changed during
transmission.
94
TIME OUT ON CTS
Hardware handshake not satisfied within
time out. Check cabling and connected
device.
95
TIME OUT ON DSR
Hardware handshake not satisfied within
time out. Check cabling and connected
device.
96
TIME OUT ON DCD
Hardware handshake not satisfied within
time out. Check cabling and connected
device.
97
CANNOT SEND EOI WITHOUT DATA
Transmission of EOI was requested when
no data was available to send.
98
ADDRESS STATUS CHANGE DURING
TRANSFER
Talker/Listener mode changed during data
transfer, possibly due to activity of
some other device on the IEEE 488 bus.
99
UNABLE TO MAKE NEW DEVICE
MakeDevice or CreateDevice was unable to
create a new device, possibly due to the
number of devices which already
existed.
100
(None)
(None)
101
COMMAND SYNTAX ERROR: %
Command interpreter was unable to
interpret command and no other
information was available.