beautypg.com

Measurement Computing Personal488 rev.3.0 For DOS & Windows 3.Xi User Manual

Page 144

background image

II. SOFTWARE GUIDES - 8. Driver488/DRV

8P. Command Descriptions

Personal488 User’s Manual, Rev. 3.0

II-129

If a command is preceded by an asterisk (

*

), that command is unasserted. For example,

*REN

states

that the remote enable line is unasserted. Conversely,

REN

without the asterisk states that the line

becomes asserted.

The bus states are further described, according to the following bus lines:

Bus State

Bus Lines

Data Transfer (DIO) Lines

8

7

6

5

4

3

2

1

Hex Value (QuickBASIC)

&H80

&H40

&H20

&H10

&H08

&H04

&H02

&H01

Decimal Value

128

64

32

16

8

4

2

1

Bus Management Lines

IFC

Interface Clear

REN

Remote Enable

IEEE 488 Interface: Bus Management Lines

ATN

Attention (&H04)

0

0

0

0

0

1

0

0

EOI

End-Or-Identify (&H80)

1

0

0

0

0

0

0

0

SRQ

Service Request (&H40)

0

1

0

0

0

0

0

0

IEEE 488 Interface: Handshake Lines

DAV

Data Valid (&H08)

0

0

0

0

1

0

0

0

NDAC

Not Data Accepted (&H10)

0

0

0

1

0

0

0

0

NRFD

Not Ready For Data (&H20)

0

0

1

0

0

0

0

0

Serial Interface: Bus Management Lines

DTR

Data Terminal Ready (&H02)

0

0

0

0

0

0

1

0

RI

Ring Indicator (&H10)

0

0

0

1

0

0

0

0

RTS

Request To Send (&H01)

0

0

0

0

0

0

0

1

Serial Interface: Handshake Lines

CTS

Clear To Send (&H04)

0

0

0

0

0

1

0

0

DCD

Data Carrier Detect (&H08)

0

0

0

0

1

0

0

0

DSR

Data Set Ready (&H20)

0

0

1

0

0

0

0

0

Bus State

Bus Commands

Data Transfer (DIO) Lines

(IEEE 488)

(ATN is asserted “1”)

8

7

6

5

4

3

2

1

Hex Value (QuickBASIC)

&H80

&H40

&H20

&H10

&H08

&H04

&H02

&H01

Decimal Value

128

64

32

16

8

4

2

1

DCL

Device Clear (&H14)

x

0

0

1

0

1

0

0

GET

Group Execute Trigger

(&H08)

x

0

0

0

1

0

0

0

GTL

Go To Local (&H01)

x

0

0

0

0

0

0

1

LAG

Listen Address Group (&H20-3F)

x

0

1

a

d

d

r

n

LLO

Local Lock Out (&H11)

x

0

0

1

0

0

0

1

MLA

My Listen Address

x

0

1

a

d

d

r

n

MTA

My Talk Address

x

1

0

a

d

d

r

n

PPC

Parallel Poll Config

x

1

1

0

S

P2

P1

P0

PPD

Parallel Poll Disable (&H07)

x

0

0

0

0

1

1

1

PPU

Parallel Poll Unconfig

(&H15)

x

0

0

1

0

1

0

1

SCG

Second. Cmd. Group (&H60-7F)

x

1

1

c

o

m

m

d

SDC

Selected Device Clear (&H04)

x

0

0

0

0

1

0

0

SPD

Serial Poll Disable (&H19)

x

0

0

1

1

0

0

1

SPE

Serial Poll Enable (&H18)

x

0

0

1

1

0

0

0

TAG

Talker Address Group (&H40-5F)

x

1

0

a

d

d

r

n

TCT

Take Control (&H09)

x

0

0

0

1

0

0

1

UNL

Unlisten (&H3F)

x

0

1

1

1

1

1

1

UNT

Untalk (&H5F)

x

1

0

1

1

1

1

1

(x = “don’t care”)