Chapter 19 - error messages, Error messages – Measurement Computing Personal488 rev.3.0 For DOS & Windows 3.Xi User Manual
Page 377
![background image](https://www.manualsdir.com/files/797818/content/doc377.png)
19. Error Messages
IV. TROUBLESHOOTING
IV-362
Personal488 User’s Manual, Rev. 3.0
19. Error Messages
Error Number and Message Text
Description
00
OK
No error has occurred.
01
TIME OUT - NOT ADDRESSED TO
LISTEN
ENTER as a Peripheral did not receive data
within the TIME OUT period.
02
AUTOINITIALIZE MODE NOT ALLOWED
This error message is obsolete in Driver488
Rev.3.0.
03
SYSTEM ERROR - BUFFER MODE NOT
SUPPORTED
Internal system error. Report to factory.
04
TIME OUT ERROR ON DATA READ
Expected bus data was not received within
the TIME OUT period.
05
SYSTEM ERROR - INVALID INTERNAL
MODE
Internal system error. Report to factory.
06
INVALID CHANNEL FOR DMA
This error message is obsolete in Driver488
Rev.4.0.
07
TIME OUT ON DMA TRANSFER
This error message is obsolete in Driver488
Rev.4.0.
08
TIME OUT - NOT ADDRESSED TO TALK
OUTPUT as a Peripheral was not possible
within the TIME OUT period.
09
TIME OUT OR BUS ERROR ON WRITE
Error occurred transferring a data byte to a
bus service.
10
SEQUENCE - NO DATA AVAILABLE
The user’s program attempted to read from
Driver488 when no response or data
was available.
11
SEQUENCE - DATA HAS NOT BEEN READ
The user’s program attempted to write data
or commands to Driver488 without
reading back the response to a previous
command.
12
SYSTEM ERROR - ON PEN INTS
ALREADY ON
Internal system error. Report to factory.
13
SYSTEM ERROR - INVALID ON PEN
INIT
Internal system error. Report to factory.
14
SYSTEM ERROR - LIKELY MEMORY
CORRUPTION
Internal system error. Report to factory.
15
SYSTEM ERROR - ON PEN INTS
ALREADY OFF
Internal system error. Report to factory.
16
BOARD DOES NOT RESPOND AT
SPECIFIED ADDRESS
Driver488 is unable to communicate with
the IEEE interface board. Check the
board address configuration, and the
software installation.
17
TIME OUT ON COMMAND (MTA)
MyTalkAddress could not be sent within the
TIME OUT period.
18
TIME OUT ON COMMAND (MLA)
MyListenAddress could not be sent within
the TIME OUT period.
19
TIME OUT ON COMMAND (LAG)
Listen address(es) could not be sent within
the TIME OUT period.
20
TIME OUT ON COMMAND (TAG)
Talk address could not be sent within the
TIME OUT period.
21
TIME OUT ON COMMAND (UNL)
UnListen could not be sent within the TIME
OUT period.
22
TIME OUT ON COMMAND (UNT)
UnTalk could not be sent within the TIME
OUT period.