Measurement Computing Personal488 rev.3.0 For DOS & Windows 3.Xi User Manual
Page 379

19. Error Messages
IV. TROUBLESHOOTING
IV-364
Personal488 User’s Manual, Rev. 3.0
47
VALUE MUST BE BETWEEN 1 AND 8
The IEEE 488 interface board clock
frequency must be between 1 and 8.
48
TIME OUT - CONTROL NOT ACCEPTED
No device took control of the IEEE 488 bus
after a PASS CONTROL.
49
UNABLE TO ADDRESS SELF TO TALK OR
LISTEN
A TALK or LISTEN subcommand in a
SEND command specified the
controller’s own address. Use MTA or
MLA instead.
50
TIME OUT ON COMMAND
A time out error occurred during a SEND
command.
51
CANNOT DMA ON ODD BOUNDARY
Internal system error. Report to factory.
52
INTERRUPT %d DOES NOT EXIST
Invalid interrupt chosen. Check hardware
settings.
53
INTERRUPT %d IS NOT SHAREABLE
Another device already controls this
interrupt.
54
UNABLE TO ALLOCATE DYNAMIC MEMORY
FOR INT %d
Internal system error. Report to factory.
55
SHARED INTERRUPT %d CHAIN
CORRUPTED
Internal system error. Report to factory.
56
TOO MANY ACTIVE TIMEOUTS
Internal system error. Report to factory.
57
INVALID DEVICE HANDLE %d
Device handle was not opened. Must first
open device and assign handle.
58
OUT OF DEVICE HANDLES
Too many device handles opened. Must
close unused handles.
59
UNKNOWN DEVICE: %s
Device not configured. Use MakeDevice to
create.
60
DRIVER NOT LOADED
Driver is not loaded. Must load driver to
run.
61
INVALID LIST OF DEVICE HANDLES
Array of device handles does not contain
valid handles.
62
INVALID TERMINATOR STRUCTURE
Terminator structure does not contain valid
data.
63
INVALID DATA POINTER
Data pointer is NULL or points to invalid
data.
64
INVALID POINTER TO STATUS
STRUCTURE
Status structure address is invalid or NULL.
65
INVALID NAME POINTER
Name parameter is empty or address is
invalid.
66
SYSTEM ERROR - INVALID INTERNAL
POINTER
Internal system error. Report to factory.
67
INVALID STRING FOR ERROR TEXT
Error text string address is invalid.
68
UNABLE TO FIND ERROR CODE
REPORTER
Internal system error. Report to factory.
69
UNABLE TO TRANSLATE ERROR CODE
Internal system error. Report to factory.
70
DMA CHANNEL %d DOES NOT EXIST
Specified DMA channel does not exist.
Check hardware settings.
71
DMA CHANNEL %d NOT AVAILABLE
Specified DMA channel is not available for
use by Driver. Choose another channel.
72
DMA CHANNEL %d ALREADY IN USE
Specified DMA channel is already being
used by another device. Choose
another channel.
73
UNABLE TO ALLOCATE MEMORY FOR
ASYNCHRONOUS I/O