beautypg.com

22 $aa8n – Measurement Computing CB-COM-7021 User Manual

Page 54

background image

54

CB-7021, CB-7022, CB-7024 User’s Manual

2.22 $AA8N

Description:

Current Value of Channel N Readback

Note

: The command is for CB-7022 and CB-7024 only.

Syntax:

$AA8N[CHK](cr)

$

Delimiter character

AA

Address of reading module (00 to FF)

8

Command for read current output value

N

Channel to readback (0 to 1 for CB-7022, 0 to 3 for CB-

7024)

Response:

Valid Command:

!AA(Data)[CHK](cr)

Invalid Command:

?AA[CHK](cr)

Syntax error or communication error may not get
response.

!

Delimiter for valid command

?

Delimiter for invalid command

AA

Address of response module (00 to FF)

(Data)

Last output command value. See Sec. 1.9 for format.

Example for CB-7024:
Command: $012

Receive: !01320614

Read address 01 configuration, returns output type 0 to 10V,

9600 bps, engineer unit format and slew rate is 1.0V/Second.

Command: #010+10.000

Receive: !01

Set address 01 channel 0 output 10.0V, returns successful.

Command: $0160

Receive: !01+10.000

Read address 01 channel 0 last output command value, re-

turns 10.000.

This manual is related to the following products: