CB-7022 Voltage Output Calibration Sequence:
1.

Connect voltmeter to module’s voltage output.

2.

Warm-Up for 30 minutes.

3.

Set output type to 2. (0 to 10V)

-> Refer Sec. 2.24.

4.

Program output 10V.

-> Refer Sec. 2.15.

5.

Check the meter and trim the output for

10V match by using trim command.-> Refer Sec. 2.18.

6.

Perform 10V Calibration Command.

-> Refer Sec. 2.21.

7.

Repeat step 1 to 6 for channel 1.