Measurement Computing CB-COM-7021 User Manual
Page 25

25
CB-7021, CB-7022, CB-7024 User’s Manual
DA Configuration of CB-7022
Analog Output Type (T)
0
0 mA to 20 mA current output
1
4 mA to 20 mA current output
2
0V to 10V voltage output
Slew Rate Control (S)
0
Immediate change
1
0.0625V/Second or 0.125 mA/Second
2
0.125V/Second or 0.25 mA/Second
3
0.25V/Second or 0.5 mA/Second
4
0.5V/Second or 1.0 mA/Second
5
1.0V/Second or 2.0 mA/Second
6
2.0V/Second or 4.0 mA/Second
7
4.0V/Second or 8.0 mA/Second
8
8.0V/Second or 16 mA/Second
9
16V/Second or 32 mA/Second
A
32V/Second or 64 mA/Second
B
64V/Second or 128 mA/Second
C
128V/Second or 256 mA/Second
D
256V/Second or 512 mA/Second
E
512V/Second or 1024 mA/Second
This manual is related to the following products: