Legrand OR-205KAN9GB-MM User Manual
Page 28

Page 21
17
Use the microscope to check the quality of the
cleave. Pointing the microscope at a white
surface will provide a brighter image. If the
cleave is unacceptable, then the fiber must be
re-prepared starting from step 11. If fiber or
fiber end-face appears dirty, reclean fiber as in
step 15.
Unacceptable cleaves
Acceptable cleave
1
2
3
*
Note: Batteries are not required.
If the Ortronics
®
Precision Cleave Tool
(OR-60300189) is used, cleave inspection
with a microscope is not required.
Turn microscope over and place fiber on stage.
Make sure fiber position is as illustrated.
Close stage and check fiber.
Slowly adjust focus knob until fiber profile is clear.
It is recommended to rotate the fiber 90˚ - 180˚ to
verify different angles
3
4
1
2
Installation: cleave inspection of 900 µm loose tube fiber
5
OptiMo Connector Installation Instructions
- OR-205KAN9GA-MM OR-205KAN9GB-SM OR-205KAN9GA-SM OR-60300128 OR-60300126 OR-205KAN9FB-MM OR-205KAN9FA-MM OR-205KAN9FB-SM OR-205KAN9FA-SM OR-205KAN9EB-MM OR-205KAN9EA-MM OR-205KAN9EBSM OR-205KAN9EA-SM OR-205KAS9GB-50T OR-205KAS9GA-50T OR-205KAS9GB-62 OR-205KAS9GA-62 OR-205KAS9GB-09 OR-205KAS9GA-09 OR-205KAS9FB-50T OR-205KAS9FA-50T OR-205KAS9FB-62 OR-205KAS9FA-62 OR-205KAS9FB-09 OR-205KAS9FA-09 OR-205KAS9EB-50T OR-205KAS9EA-50T OR-205KAS9EB-62 OR-205KAS9EA-62 OR-205KAS9EB-09 OR-205KAS9EA-09