To be installed by a certified electrician or other qualified person.

WARNING – To prevent severe shock or electrocution, always turn power
OFF at the service panel before installing this unit, working on the circuit, or
changing a lamp.

CAUTION – To reduce the risk of overheating and possible damage to other
equipment, do not install incandescent dimmer to control a receptacle, a
fluorescent light, a motor-operated appliance, or a transformer-supplied
appliance.

Do not use dimmer with incandescent lamps whose power requirements
exceeds maximum power (stated in Watts) of the dimmer.

Do not connect dimmer to power source other than 120VAC, 60 Hz only.

Use copper wire only.

DIRECTIONS

1. Disconnect power to circuit by removing fuse or turn circuit breakers OFF

before installing.

2. Remove wall plate and switch mounting screws, pull existing switch from

wall box.

3. Disconnect existing switch from circuit.

3-way installation: Identify the

“COMMON” wire (wire connected to the terminal marked common or odd
colored terminal). For “new” installation identify wire connected to power
source or to the load.

4. Connect dimmer as shown in the installation diagram with wire connectors

provided.

5. Install dimmer in wall box, with words on the dimmer right side up, using

mounting screws provided.

6. Attach wall plate, then restore power to the circuit.

NOTE: It is normal for the dimmer to feel warm during operation. A 50W
minimum load is required. Use a separate neutral wire for each phase of a
multiphase system containing a dimmer, and for high power single phase
applications where flickering is present.

DIMMER TYPES

INSTALLATION DIAGRAM (wiring is same with each of dimmer types)

MULTIPLE GANGING OF DIMMERS

Any combination of dimmer models may be ganged together. Using vise or
heavy-duty pliers, remove the outer fins on either or both sides, as necessary,
at the break-off points on the thin metal line at the base of the third fin.
Dimmers can be ganged without removing fins by proper selection and
placement of outlet boxes. When fins are removed, de-rate the maximum load
according to the following De-Rating Table:

MAXIMUM

FINS REMOVED

LOAD

ONE SIDE

TWO SIDES

1000W

800W

700W

1500W

1400W

1300W

2000W

1800W

1600W

CAUTION : Sharp or jagged metal edges might be exposed where sections
were broken off. Use care when handling the dimmer after this operation.

ILLUSTRATION FOR GANGING

HOW TO CUT PLASTIC FACEPLATE:

If fins are removed for ganging, the faceplate must be adjusted to match.

You may either score the groove on the back of the faceplate thoroughly with
a razor sharp packing knife, or you may partially score the groove, then
complete the break with pliers.

TO CUT THE FACEPLATE WITH KNIFE ONLY:

1. Lay faceplate face down on soft clean cloth,

on a flat solid surface to preserve finish.

2. Run knife vertically throughout groove

repeatedly until plastic separates.

3. Dress rough edges using very fine-grained

sand paper.

TO CUT THE FACEPLATE USING PLIERS AND KNIFE:

1. Lay faceplate face down on soft clean

cloth, on a flat solid surface to preserve
finish.

2. Run knife vertically throughout groove

several times.

3. Hold faceplate firmly in one hand and use

pliers to bend the flat edge of the fin away from the groove. Behind the
opposing ends first, then make a final break at the middle, separating fin
from faceplate.

4. Dress rough edges using very fine-grained sand paper.

INSTALLATION INSTRUCTIONS

INCANDESCENT DIMMERS

R E A D A N D S A V E T H E S E I N S T R U C T I O N S !

Double-Gang

Rotary

Slide

Toggle

Mixed Combination-Gang

Fin Break-Off Points

WIRE NUT USAGE CHART

Use Only Copper Wire With This Device

Wire Combinations

Strips Lengths

Color

1#14 & 1#16; 1#14 & 2#18; 2,3#16; 1#16 & 1-3#18;

1/2" Except 9/16"

Orange

3-5#18; 2#18

For #16 & #18 AWG

1#10 & 1#14; 1#12 & 1#14 2,3#14; 2#14 &1,2#16;

1/2" Except 5/8"

Yellow

2#14 & 2,3#18;1#14 & 1-4#16; 1#14 & 1-4#18

For #18 AWG

1#10 & 1,2#12; 1#10 & 1-3#14; 2,3#12; 1#12 &

7/16" Except 1/2"

Red

1-3#14; 1#12 & 3#16; 3,4#14

For #16

1#14 & 1,2#16; 1#14 & 1,2#18; 2,3#16; 2-5#18

7/16" For #14 & #16

Ivory

1/2" For #18

GREEN

T

O

GROUND

BLACK

NEUTRAL

WHITE

BLACK

TO 120V SOURCE
TO LAMPS

GREEN

T

O

GROUND

RED

BLACK OR
YELLO

W

TO 3 WAY SWITCH

NEUTRAL

WHITE

BLACK

COMMON

Single Pole

Three Way