3.1.2.1. pump head indicator, 3.1.2.2. nozzle indicator – Gasboy SiteOmat Users Manual User Manual
Page 35

The Pump Head On-Line Data is displayed in five text boxes and two indicators. The fueling
process is viewed in real-time, as if watching the display on the fuel pump. The textual information
displayed on-line is as follows:
a. USD:
The amount of money, which should be collected for the fuel dispensed so
far
b. Gallon:
The fuel volume dispensed so far
c. Emp/Veh:
The Employee name or plate number of the vehicle being fueled
d. Nz:
The number of the nozzle dispensing the fuel
e. Fleet:
The number of the fleet, to which the fueled vehicle belongs
4-3.1.2.1. Pump Head Indicator
The pump head indicator displays the number of the pump head. The following states are displayed
by the pump head color indicator:
Red:
The pump head is not defined
Green:
The pump head is monitored
Black:
The pump head is blocked (deactivated)
4-3.1.2.2. Nozzle Indicator
The nozzle indicator displays the state of the nozzle of each pump head. The nozzle icon changes
according to the nozzle state, as follows:
a.
Idle – awaiting fueling request
b.
Call status – the fuel nozzle was lifted
c.
In-Use – fuel is being dispensed
d.
Pay status – transaction is completed and money is collected
e.
Ready – fueling was authorized but the nozzle was not lifted yet
f.
Stop – Fueling is stopped (e.g. nozzle is pulled out before fueling was completed)
g.
Attention – A problem of some sort occurred (i.e. pump in error, communication error)
SiteOmat User’s Manual– MDE 4818