1-2.3. Internal Communication Alternatives

OrCU can communicate with the other modules in the Island Controller system over:

a. TCP/IP Ethernet over CAT5e wires (some modules require the CommVerter Module as the

interface)

b. RS-485 links (segmentation to several links is available)

c. 8 Port CommVerter system

1-2.4. External Communication Alternatives

Communication with external management and data processing systems, for reports and
clearinghouse, can be provided by:

a. Direct - Ethernet or RS-232

b. ADSL/ISDN Modem

c. Dial-Up Modem (not recommended)

d. GPRS, Cellular modem.

1-2.5. Data Access Methods

OrCU is a web server over an SQL transaction database. It uses a secured link with several levels
of authentication. Logging into the SiteOmat is done with a standard browser from any PC and a
static IP address. Data is available in real time using pre-defined active forms.

Real-time data is available via an on-line connection, a dedicated line or Internet/Intranet (Secured)
link. The Station Controller system with SiteOmat enables real-time monitoring of a vehicle
refueling process including Volume, Price and all vehicle details.

The SiteOmat Station Controller supports exporting (transactions) and importing (Negative/Positive
lists) data using a pre-defined format.

1-3. ORCU

Orpak Controller Unit (OrCU) is a complete forecourt controller with its own embedded operating
system (see Figure 1-2). The unit consists of an embedded hardware platform with a solid state
Flash hard disk, Real Time Clock (RTC) with back up, along with surge suppressors for transient
and noise immunity. It also includes power fail recovery mechanisms.

OrCU features two separate and isolated networks (TCP/IP over Ethernet). One network links the
Islander PLUS system components. The second network is intended for external remote
communication (Head Office, 3

rd

party systems). This network is protected by SSL security.

OrCU includes a Security Access Module (SAM) for enhanced data protection and safe security key
storage (Triple DES encryption). OrCU includes a built-in server for Web access through Internet
Explorer 7.0 or higher.