beautypg.com

Console settings, Slip settings – D-Link DES-3326 User Manual

Page 103

background image

DES-3326 Layer 3 Fast Ethernet Switch User’s Guide

Figure 6-18. Serial Port Settings screen

Toggle the Serial port setting field to select either the Console or SLIP protocol.

The following fields can then be set:

Console Settings

Parameter Description

Baud Rate

Displays the serial bit rate used to
communicate with a management
station. The console baud rate is 9600
bits per second.

Data bits

Displays the number of bits that make
up a word when communicating with
the management station. The console
interface uses 8 data bits.

Stop bits

Displays the number of bits used to
indicate that a word has been
completely transmitted. The console
interface uses 1 stop bit.

Auto-Logout

This sets the time the interface can be
idle before the switch automatically
logs-out the user. The options are 2
mins
, 5 mins, 10 mins, 15 mins, or
Never.

SLIP Settings

Parameter Description

Baud Rate

Sets the serial bit rate that will be used
to communicate the next time the
Switch is restarted. Applies only when
the serial port is being used for out-of-
band (SLIP) management; it does not

103