View display – Daktronics Pro Series Operations and Maintenance Manual User Manual
Page 95

VIEW DISPLAY
When VIEW is touched, up to sixty battens are
displayed (Figure 12.2). This will cover most
VAC installations.
If the installation has more than 60 motors, use
the Previous and Next buttons to display all
of the battens.
Each batten displayed shows the upper and lower
limits bars, the current position and the name.
If the name is blue, then the display represents
a group. If the name is red, the batten is
disabled. If the display is red, the batten
is faulted (Figure 12.3).
Figure 12.2: View panel with Previous and Next
buttons highlighted.
Figure 12.3: Different batten displays for View panel
Upper limit
Current position
Lower limit
Motor Group
name
Normal
Group
i-Batten
bypassed
i-Batten
faulted
Disabled
88