5. Set the maximum speed of the motor using
the slider control (Figure 9.8).
Depending on what is attached to the batten,
you may wish to limit how fast the motor can
move. By dragging the slider change the
motor’s maximum speed can be changed.
6. The i-Batten sensitivity value determines how
much the batten’s weight must change to
register a fault.
Touch SET SENSITIVITY (Figure 9.9) to
display a keypad to enter the sensitivity value
(Figure 9.10). After entering the sensitivity,
i-Batten system is ready for the teach setup.
WARNING
The cables are rated for 420 lbs.
of support. Overloading the batten
could cause the cables to break.
Figure 9.8: Maximum speed slider
Figure 9.9: Set Sensitivity button
Figure 9.10: Sensitivity keypad