4.2.8 REGISTERS Menu

The registers menu provides access to the non-voltage setup storage of the power source. A
total of 8 front panel setups can be stored in registers numbered from 0 through 7. Each register
except register 0 can hold the complete front panel setup, including the programmed transient
list. This allows for quick recall of different setups and transient programs.

Register 0 is reserved to be used as the power-on setting as assigned by the user. To have the
power source start in a specific setting, save the desired setting to Register 0 and assign register
zero as the power-on default in the CONFIGURATION menu. Alternatively, the Lx/Ls can be set
to power up with the RST factory default settings. See 4.9 for factory default settings.

ENTRY

DESCRIPTION

SAVE

REG 0

– 7

Saves the selected setup and transient list
from memory. (Setup only for Reg 0) The left
knob (Voltage) may be used to scroll through
the available list of setup register numbers.
Use the ENTER key to perform the save
operation.
Register 0 can be assigned as the power-on
state setup from the CONFIGURATION menu.
A valid setup must be saved in REG0 to do so.

Note that REG0 only saves the setup, not the
transient list. All other registers also save the
transient list.

RECALL

REG 0

– 7

Recalls the selected setup and transient list to
memory. (Setup only for Reg 0) The left knob
(Voltage) may be used to scroll through the
available list of setup register numbers.
Use the ENTER key to perform the recall
operation.
Register 0 can be assigned as the power-on
state setup from the CONFIGURATION menu.
A valid setup must be saved in REG0 to do so.

Note that REG0 only saves the setup, not the
transient list. All other registers also save the
transient list.