beautypg.com

AMETEK Ls Series User Manual

Page 147

background image

User Manual

Lx / Ls Series

143

SAC 110 Tests

– Revisions B, C, D, E, F

SAC110

Normal Frequency Transients, Rev B, C, D, E, F

Condition

Duration (s)

Over Frequency

A

410 Hz, 10 sec, tr = 40 msec, tf = 40 msec

100

B

420 Hz, 5 sec, tr = 80 msec, tf = 80 msec

80

C

425 Hz, 1 sec, tr = 100 msec, tf = 100 msec

60

D

425 Hz, 1 sec, tr = 100 msec, tf = 10 msec

100

420 Hz, 4 sec, tr = 10 msec, tf = 20 msec

410 Hz, 5 sec, tr = 20 msec, tf = 40 msec

Under Frequency

E

390 Hz, 10 sec, tr = 40 msec, tf = 40 msec

100

F

380 Hz, 5 sec, tr = 80 msec, tf = 80 msec

80

G

375 Hz, 1 sec, tr = 100 msec, tf = 100 msec

60

H

375 Hz, 1 sec, tr = 100 msec, tf = 10 msec

100

380 Hz, 4 sec, tr = 10 msec, tf = 20 msec

390 Hz, 5 sec, tr = 20 msec, tf = 40 msec

Combined

I

375 Hz, 1 sec, tr = 100 msec, tf = 100 msec

62

425 Hz, 1 sec, tr = 100 msec, tf = 100 msec

SAC 110 Tests

– Revisions A

SAC110

Normal Frequency Transients, Rev A

Condition

Duration (s)

Over Frequency

A

430 Hz, 0.5 cycle, tr = 120 msec, tf = 120 msec

100

B

430 Hz, 0.5 cycle, tr = 300 msec, tf = 1.2 sec

80

C

450 Hz, 0.5 cycle, tr = 200 msec, tf = 200 msec

60

D

450 Hz, 0.5 cycle, tr = 250 msec, tf = 3 sec

100

Under Frequency

E

370 Hz, 0.5 cycle, tr = 120 msec, tf = 120 msec

100

F

370 Hz, 0.5 cycle, tr = 300 msec, tf = 1.2 sec/

80

G

350 Hz, 0.5 cycle, tr = 200 msec, tf = 200 msec

60

H

350 Hz, 0.5 cycle, tr = 250 msec, tf = 3 sec

100

Combined

I

350 Hz, 0.5 cycle, tr = 200 msec, tf = 200 msec

62

450 Hz, 0.5 cycle, tr = 200 msec, tf = 200 msec

This manual is related to the following products: