beautypg.com

AMETEK Ls Series User Manual

Page 19

background image

User Manual

Lx / Ls Series

15

Output Parameter

Specification

voltage range.
Current in High voltage range is reduced by a factor of 2.

Note:

For 9000Ls/2 and 12000Ls/2, currents are 2 x 4500Ls and 6000Ls.
For 13500Ls/3 and 18000Ls/3, currents are 3 x 4500Ls and 6000Ls

Maximum Current at Full Scale Voltage

– Lx Series

Model

3000Lx

4500Lx

6000Lx

Single Phase Mode:
Max. RMS, low Vrange

20 A

30 A

38.4 A

Three Phase Mode:
Max. RMS, low Vrange
per phase

6.67 A

10 A

12.8 A

Current Limit mode

Programmable, CC or CV mode

Maximum Current at Full Scale Voltage

– Ls Series

Model

3000Ls

4500Ls

6000Ls

Single Phase Mode:
Max. RMS, low Vrange

22.2 A

33.3 A

44.4 A

Three Phase Mode:
Max. RMS, low Vrange
per phase

7.4 A

11.1 A

14.8 A

Current Limit mode

Programmable, CC or CV mode

Repetitive Peak Current

Model

3000Lx / Ls

4500Lx / Ls

6000Lx / Ls

Max. Peak Current:

6 x RMS current at FS

4 x RMS current at FS

3 x RMS current at FS

Note: For 9000Lx / Ls /2 and 12000Lx / Ls /2, currents are 2 x 4500Lx/Ls and 6000Lx/Ls.

For 13500Lx / Ls/3 and 18000Lx / Ls /3, currents are 3 x 4500Lx/Ls and 6000Lx/Ls

Frequency

Range:

45 Hz - 1000 Hz

Resolution

1

:

0.01 Hz

[< 81.91 Hz]

0.1 Hz

[> 82.0 to 819.1 Hz]

1 Hz

2

[> 819 Hz]

Accuracy:

± 0.025 %

Temp. Coefficient

± 5 ppm of value / °C

Stability:

± 15 ppm of value

Phase (3 phase mode)

Range:

Phase B/C relative to phase A

0.0 to 360.0°

Resolution:

0.1° < 819.1 Hz
0.5° > 819.1 Hz

Accuracy:

< 1°

[45 Hz - 1000 Hz]

< 1° + 1°/kHz

[> 1000 Hz]

1

Programming resolution reduced if

–LKM/-LKS option is installed. See paragraphs 2.6.5 and 2.7.5.

2

Programming resolution of 0.5 Hz above 819.1 Hz may be used over the remote control bus with ± 0.5 Hz

accuracy.

This manual is related to the following products: