AMETEK Ls Series User Manual
Page 19

User Manual
Lx / Ls Series
15
Output Parameter
Specification
voltage range.
Current in High voltage range is reduced by a factor of 2.
Note:
For 9000Ls/2 and 12000Ls/2, currents are 2 x 4500Ls and 6000Ls.
For 13500Ls/3 and 18000Ls/3, currents are 3 x 4500Ls and 6000Ls
Maximum Current at Full Scale Voltage
– Lx Series
Model
3000Lx
4500Lx
6000Lx
Single Phase Mode:
Max. RMS, low Vrange
20 A
30 A
38.4 A
Three Phase Mode:
Max. RMS, low Vrange
per phase
6.67 A
10 A
12.8 A
Current Limit mode
Programmable, CC or CV mode
Maximum Current at Full Scale Voltage
– Ls Series
Model
3000Ls
4500Ls
6000Ls
Single Phase Mode:
Max. RMS, low Vrange
22.2 A
33.3 A
44.4 A
Three Phase Mode:
Max. RMS, low Vrange
per phase
7.4 A
11.1 A
14.8 A
Current Limit mode
Programmable, CC or CV mode
Repetitive Peak Current
Model
3000Lx / Ls
4500Lx / Ls
6000Lx / Ls
Max. Peak Current:
6 x RMS current at FS
4 x RMS current at FS
3 x RMS current at FS
Note: For 9000Lx / Ls /2 and 12000Lx / Ls /2, currents are 2 x 4500Lx/Ls and 6000Lx/Ls.
For 13500Lx / Ls/3 and 18000Lx / Ls /3, currents are 3 x 4500Lx/Ls and 6000Lx/Ls
Frequency
Range:
45 Hz - 1000 Hz
Resolution
1
:
0.01 Hz
[< 81.91 Hz]
0.1 Hz
[> 82.0 to 819.1 Hz]
1 Hz
2
[> 819 Hz]
Accuracy:
± 0.025 %
Temp. Coefficient
± 5 ppm of value / °C
Stability:
± 15 ppm of value
Phase (3 phase mode)
Range:
Phase B/C relative to phase A
0.0 to 360.0°
Resolution:
0.1° < 819.1 Hz
0.5° > 819.1 Hz
Accuracy:
< 1°
[45 Hz - 1000 Hz]
< 1° + 1°/kHz
[> 1000 Hz]
1
Programming resolution reduced if
–LKM/-LKS option is installed. See paragraphs 2.6.5 and 2.7.5.
2
Programming resolution of 0.5 Hz above 819.1 Hz may be used over the remote control bus with ± 0.5 Hz
accuracy.