beautypg.com

AMETEK Ls Series User Manual

Page 38

background image

User Manual

Lx / Ls Series

34

Parameter

Supplemental Specification

Frequency

Range Standard Lx:

45

– 819 Hz

With

–HF option:

45 - 5000 Hz.

Resolution Standard Lx:

0.1 Hz

With

–HF option:

1 Hz

Accuracy ± 0.025%

Phase

Phase Resolution Standard:

standard specifications apply.

With

–HF option:

0.5°

Phase Accuracy Standard:

standard specifications apply.

With

–HF option:

< 2° + 1°/kHz

2.7.6

–EXS Option Ls Series - Supplemental Specifications

The

–EXS (External Sync) option allows the output frequency of the AC source to be synchronized to an

external TTL level clock signal.

The following supplemental specifications apply when the Ls is configured with the external sync option. (-
EXS).

Parameter

Supplemental Specification

Input

Voltage Input TTL Level square wave.

Impedance 10 KOhm.

Frequency

Range Same as internal clock mode. See configuration limits.

Max Sync Input Slew Rate < 80 Hz / sec.

Changes in sync input frequency occurring faster than this rate will result in
Error 804: External Sync Error. Output relay is opened on Error.

Max Sync Step < 20 Hz.

Sudden changes in sync input frequency greater than 20 Hz will result in
Error 804: External Sync Error. Output relay is opened on Error.

Mode Selection

When switching between INT and EXT sync mode, the output of the AC
source will be dropped momentarily.

Restrictions

Frequency cannot be programmed in external sync mode.
Frequency transient list system is not available in sync mode.
Transient list dwell times are not correlated to external sync but based on
internal timebase.