2.7 Available Options
– Ls Series
Output Options
-AX
Auxiliary outputs, 5 VAC and 26 VAC, 400 Hz. (Output D and E)
- HV
156 / 312 V range output
- EHV
200 / 400 V range output
-HF
High frequency option. Increases output frequency to 5000 Hz (single
chassis configurations) or 2000 Hz (multi-chassis models).
-LF
Low frequency option. Limits maximum output frequency to 500 Hz.
-MODE
Adds single phase and three phase mode switching capability to
–3 LS
models. Not available on
–1 models.
Firmware Options
- 704
Mil Std 704 test firmware.
Includes AC tests for Revisions D and E
- 704F
Mil Std 704 test firmware.
Includes AC tests for Revisions A through F
- 160
RTCA/DO-160D test firmware.
Includes RCTA-DO160D, section 16, Change #2 and EURO/CAE-14D
AC tests only.
Misc. Options
-ADV
Advanced features package. Adds arbitrary waveform generation and
harmonic analysis measurements. For specifications, see Lx Series.
-GPIB
GPIB interface. Also adds APE command language support for
backward compatibility with L Series. See Lx/Ls Programming Manual
P/N 7004-961 for detail on APE command language.
-L22
Locking Knobs. Shaft lock screws replace knobs to prevent turning of
Voltage and Frequency shuttles.
-LKM
Clock and Lock Master. Enables synchronizing outputs of two Lx AC
sources, one acting as master.
This mode supports a frequency range of 45 to 819 Hz on standard
Lx/Ls models. See section 3.9.
-LKS
Clock and Lock Auxiliary. See -LKM for details. (See Notes, see section
3.9.)
-LNS
Line Sync (see Notes)
-EXS
External Sync (see Notes)
-RMS
Set of 2 Rack mount slides. (Left and Right) Recommended to mount Lx
Chassis in 19 inch instrument cabinet.
Notes:
External Trigger input is standard.
Line sync and External sync are mutually exclusive.
External Trigger input and External sync are mutually exclusive.
Units with -LKS (auxiliary) cannot have Line Sync or External Sync.