AMETEK Ls Series User Manual
Page 162

User Manual
Lx / Ls Series
158
TAC 301 Tests
– Revisions C, E, F
TAC301
Abnormal SS Limits Volt and Freq Rev C, E, F
Condition
Duration (s)
Nominal Voltage
A
Vnom 115V, Flow 380 Hz
1800
B
Vnom 115V, Fhigh 420 Hz
1800
Low Voltage
C
Vlow 100V, Fnom 400 Hz
1800
D
Vlow 100V, Flow 380 Hz
1800
E
Vlow 100V, Fhigh 420 Hz
1800
High Voltage
F
Vhigh 125V, Fnom 400 Hz
1800
G
Vhigh 125V, Flow 380 Hz
1800
H
Vhigh 125V, Fhigh 420 Hz
1800
TAC 301 Tests
– Revisions B, D
TAC301
Abnormal SS Limits Volt and Freq Rev B, D
Condition
Duration (s)
Nominal Voltage
A
Vnom 115V, Flow 375 Hz
1800
B
Vnom 115V, Fhigh 425 Hz
1800
Low Voltage
C
Vlow 100V, Fnom 400 Hz
1800
D
Vlow 100V, Flow 375 Hz
1800
E
Vlow 100V, Fhigh 425 Hz
1800
High Voltage
F
Vhigh 125V, Fnom 400 Hz
1800
G
Vhigh 125V, Flow 375 Hz
1800
H
Vhigh 125V, Fhigh 425 Hz
1800
TAC 301 Tests
– Revisions A
TAC301
Abnormal SS Limits Volt and Freq Rev A
Condition
Duration (s)
Nominal Voltage
A
Vnom 115V, Flow 370 Hz
1800
B
Vnom 115V, Fhigh 430 Hz
1800
Low Voltage
C
Vlow 102V, Fnom 400 Hz
1800
D
Vlow 102V, Flow 370 Hz
1800
E
Vlow 102V, Fhigh 430 Hz
1800
High Voltage
F
Vhigh 124V, Fnom 400 Hz
1800
G
Vhigh 124V, Flow 370 Hz
1800
H
Vhigh 124V, Fhigh 430 Hz
1800