2.7.1 -HV Option Ls Series - Supplemental Specifications

Specifications for Ls units with -HV voltage range option installed are same as standard Ls unit
except where noted below.

Voltage:

Ranges (L-N):

Low range

0 - 156 Vrms

High range

0 - 312 Vrms

Maximum Current at Full Power

Note: Current, maximum amps per phase available at on low voltage range. 3000Ls and 4500Ls

operate in constant power mode up to currents shown at reduced voltage. See Figure 2-1.
For 9000Ls/2 and 12000Ls/2, currents are 2 x 4500Ls and 6000Ls.
For 13500Ls/3 and 18000Ls/3, currents are 3 x 4500Ls and 6000Ls

Model

3000Ls-HV

4500Ls-HV

6000Ls-HV

Single Phase Mode:
Max. RMS, low Vrange

38.4 A

38.4 A

38.4 A

Three Phase Mode:
Max. RMS, low Vrange
per phase

12.8 A

12.8 A

12.8 A

Note:

Current derates linearly from 50% of voltage range to 20% of specified current at 10% of
voltage range.
Current in High voltage range is reduced by a factor of 2.

Note:

For 9000Ls/2-HV and 12000Ls/2-HV, currents are 2 x 4500Ls-HV and 6000Ls-HV.
For 13500Ls/3-HV and 18000Ls/3-HV, currents are 3 x 4500Ls-HV and 6000Ls-HV