beautypg.com

AMETEK Ls Series User Manual

Page 18

background image

User Manual

Lx / Ls Series

14

Output Parameter

Specification

Single Phase Mode

13.5 KVA

5.76 KVA

12 KVA

15 KVA

Three Phase Mode (per

phase)

4.5 KVA

17.3 KVA

4 KVA

5 KVA

Power

– Ls Series (total power for all phases, either range, at full scale voltage)

35° C Ambient

50° C Ambient

Model

3000Ls

4500Ls

6000Ls

3000Ls

4500Ls

6000Ls

Single Phase Mode

3 KVA

4.5 KVA

6 KVA

3 KVA

4 KVA

5 KVA

Three Phase Mode (per

phase)

1 KVA

1.5 KVA

2 KVA

1 KVA

1.35 KVA

1.7 KVA

Model

9000Ls/2

12000Ls/2

9000Ls/2

12000Ls/2

Single Phase Mode

9 KVA

12 KVA

8 KVA

10 KVA

Three Phase Mode (per

phase)

3 KVA

4 KVA

2.7 KVA

3.3 KVA

Model

13500Ls/3

18000Ls/3

13500Ls/3

18000Ls/3

Single Phase Mode

13.5 KVA

6 KVA

12 KVA

15 KVA

Three Phase Mode (per

phase)

4.5 KVA

18 KVA

4 KVA

5 KVA

Maximum Current at Full Power

– Lx Series

Note: Current, maximum amps per phase available at on low voltage range. 3000Lx and 4500Lx

operate in constant power mode up to currents shown at reduced voltage. See Figure 2-1.
For 9000Lx/2 and 12000Lx/2, currents are 2 x 4500Lx and 6000Lx.
For 13500Lx/3 and 18000Lx/3, currents are 3 x 4500Lx and 6000Lx

Model

3000Lx

4500Lx

6000Lx

Single Phase Mode:
Max. RMS, low Vrange

38.4 A

38.4 A

38.4 A

Three Phase Mode:
Max. RMS, low Vrange
per phase

12.8 A

12.8 A

12.8 A

Note:

Current derates linearly from 50% of voltage range to 20% of specified current at 10% of
voltage range.
Current in High voltage range is reduced by a factor of 2.

Note:

For 9000Lx/2 and 12000Lx/2, currents are 2 x 4500Lx and 6000Lx.
For 13500Lx/3 and 18000Lx/3, currents are 3 x 4500Lx and 6000Lx

Maximum Current at Full Power

– Ls Series

Note: Current, maximum amps per phase available at on low voltage range. 3000Ls and 4500Ls

operate in constant power mode up to currents shown at reduced voltage. See Figure 2-1.
For 9000Ls/2 and 12000Ls/2, currents are 2 x 4500Ls and 6000Ls.
For 13500Ls/3 and 18000Ls/3, currents are 3 x 4500Ls and 6000Ls

Model

3000Ls

4500Ls

6000Ls

Single Phase Mode:
Max. RMS, low Vrange

44.4 A

44.4 A

44.4 A

Three Phase Mode:
Max. RMS, low Vrange
per phase

14.8 A

14.8 A

14.8 A

Note:

Current derates linearly from 50% of voltage range to 20% of specified current at 10% of

This manual is related to the following products: