10.7.5 SXF Group Tests
Single phase 60 Hz AC tests
Note: 60 Hz frequency tests are part of revision F only. There are no equivalent tests in
revision A through E.
SXF 102 Tests
– Revision F
SXF102
Steady State Voltage and Frequency - Rev C-F
Condition
Duration (s)
Nominal Voltage
A
Vnom=115V, Fnom=60 Hz - Nominal
1800
B
Vnom=115V, Flow=59.5 Hz - Nominal
1800
C
Vnom=115V, Fhigh=60.5 Hz - Nominal
1800
Low Voltage
D
Vlow =105V, Fnom=60 Hz - Low
1800
E
Vlow=105V, Flow= 59.5 Hz- Low
1800
F
Vlow=105V, Fhigh=60.5 Hz - Low
1800
High Voltage
G
Vhigh=125V, Fnom=60 Hz - High
1800
H
Vhigh=125V, Flow=59.5 Hz- High
1800
I
Vhigh=125V, Fhigh=60.5 Hz - High
1800
SXF 103 Tests
Voltage Phase Difference tests do not apply for single-
phase EUT’s.
SXF 104 Tests
– Revision F
SXF104
Voltage Modulation Rev F
Condition
Duration (s)
A
Vmod F = 1.0 Hz, V = 0.375 Vrms
1800
B
Vmod F = 1.5 Hz, V = 2.5 Vrms
1800
C
Vmod F = 4 Hz, V = 2.5 Vrms
1800
D
Vmod F = 10 Hz, V = 0.375 Vrms
1800
E
Vmod F = 15 Hz, V = 0.375 Vrms
1800
F
Vmod F = 30 Hz, V = 0.375 Vrms
1800
SXF 105 Tests
– Revisions E, F
SXF105
Frequency Modulation Rev F
Condition
Duration (s)
A
Fmod F = 0.1 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz
1800
B
Fmod F = 0.5 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz
1800
C
Fmod F = 4 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz
1800
D
Fmod F = 25 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz
1800
E
Fmod F = 15 Hz/sec, Fmod Amp = 0.5 Hz± 0.25 Hz
1800