AMETEK Ls Series User Manual
Page 75
User Manual
Lx / Ls Series
71
ENTRY
DESCRIPTION
the front panel using the ENTER key.
BUS
Bus mode. The transient system is started by a
bus command or a group execute trigger (GET).
EXT
External mode. The transient system is started
by a user-provided external TTL trigger signal on
TRIGGER IN1.
TRAN STEP
Indicates the transient system execution mode. Available
modes are:
AUTO
When triggered, the transient system will
automatically execute each list point sequentially
without waiting for a trigger between list points.
This execution is paced by the dwell time set for
each data point.
ONCE
When triggered, the transient system will
execute the first list point and wait for a new
trigger once the dwell time expires. This allows
triggered execution of each step in the transient
list.
List parameters:
VOLT
Step #
Voltage set point
VSLEW
Step #
Voltage slew rate in V/sec
FREQ
Step #
Frequency set point
FSLEW
Step #
Frequency slew rate in Hz/sec
FUNC
Step #
Waveform selection. Available choices are Sine,
Square, Clipped or any of the user provided
waveforms in waveform memory.
PAUSE
Step #
Delay
CURR
Step #
Current set point
PHASE
Step #
Phase angle set point. (Not relevant for phase A
if clock mode is internal.)
DWELL
Step #
Dwell time in seconds.
Range is 0.001 to 900000
TTLT
Step #
ON:
Generates an output trigger pulse at this
list step.
OFF:
No output trigger.
The output trigger is available on the TRIG