Clock summary – Altera Arria V GZ Avalon-ST User Manual
Page 145

Clock Summary
Table 7-4: Clock Summary
Name
Frequency
Clock Domain
coreclkout_hip
62.5, 125 or 250 MHz
Avalon-ST interface between the Transaction and
Application Layers.
pld_clk
62.5, 125, or 250 MHz
Application and Transaction Layers.
refclk
100 or 125 MHz
SERDES (transceiver). Dedicated free running input
clock to the SERDES block.
reconfig_xcvr_clk
100 –125 MHz
Transceiver Reconfiguration Controller.
hip_reconfig_clk
50–125 MHz
Avalon-MM interface for Hard IP dynamic reconfi‐
guration interface which you can use to change the
value of read-only configuration registers at
run-time. This interface is optional. It is not
required for Arria 10 devices.
7-8
Clock Summary
UG-01127_avst
2014.12.15
Altera Corporation
Reset and Clocks